Start-SbecLogSession is accessible with the help of BootEventCollector module. To configure BootEventCollector, go through this link.
Synopsis
Starts an ETW log session.
Description
The Start-SbecLogSession cmdlet starts an Event Tracing for Windows (ETW) log session with full flexibility.
To start an ETW session in a simpler way with fewer parameters, use the Start-SbecSimpleLogSession cmdlet.
Parameters
-BufferSize
Specifies the buffer size for the session, in kilobytes. This is the size of one buffer, with the count of these buffers set by the MinimumBufferCount and MaximumBufferCount parameters.
Type: | UInt32 |
Position: | 7 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-ClockType
Specifies the type of clock used for the events collected by this session: The acceptable values for this parameter are:
- Default
- QueryPerformanceCounter. The high-resolution (period of 100 nanoseconds) clock that is typically used for performance measurement.
- SystemTime. The lower-resolution system time similar to FILETIME (period of 10 milliseconds). This value is most typical for the data collection through SBEC.
- CpuCycleCounter. The highest-resolution, with the frequency of the CPU, but may be unreliable depending on the CPU model and the thermal and power modes.
Type: | ClientContext |
Accepted values: | Default, QueryPerformanceCounter, SystemTime, CpuCycleCounter |
Position: | 6 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-FlushSeconds
Specifies the timeout, in seconds, for the session buffers to automatically flush. You can disable the flushing of buffers on timeout by setting this parameter to 0, then the buffers will be written only when full or on an explicit flush.
Type: | UInt32 |
Aliases: | FlushTimer |
Position: | 11 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-KernelEnableFlags
Specifies flags for the NT Kernel Logger that enable the kernel events. For the setup and boot monitoring, the only reasonable flag is Process. This enumeration type is defined in $PsHome\Modules\BootEventCollector\SbecTraceHelpers.psm1. The acceptable values for this parameter are:
- Process
- Thread
- ImageLoad
- ProcessCounters
- ContextSwitch
- Dpc
- Interrupt
- SystemCall
- DiskIO
- DiskFileIO
- DiskIOInit
- Dispatcher
- MemoryPageFaults
- MemoryHardFaults
- VirtualAlloc
- NetworkTCPIP
- Registry
- Alpc
- SplitIO
- Driver
- FileIO
- FileIOInit
- Profile
Type: | EventTraceFlag |
Accepted values: | None, Process, Thread, ImageLoad, ProcessCounters, ContextSwitch, Dpc, Interrupt, SystemCall, DiskIO, DiskFileIO, DiskIOInit, Dispatcher, MemoryPageFaults, MemoryHardFaults, VirtualAlloc, NetworkTCPIP, Registry, Alpc, SplitIO, Driver, FileIO, FileIOInit, Profile |
Position: | 13 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-Level
Specifies the highest detail level value to enable for providers. This enumeration type is defined in $PsHome\Modules\BootEventCollector\SbecTraceHelpers.psm1. The acceptable values for this parameter are:
- Undefined
- Fatal
- Error
- Warning
- Information
- Verbose
- All
Type: | SeverityLevel |
Accepted values: | Undefined, Fatal, Error, Warning, Information, Verbose, All |
Position: | 5 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-LogFileMode
Specifies the new flags for the log file mode. The EnableKd and DisableKd values parameters are applied on top of these flags. This enumeration type is defined in $PsHome\Modules\BootEventCollector\SbecTraceHelpers.psm1. The cmdlet automatically adds the RealTime and KdFilter values to this parameter. Commonly used values are:
- FileSequential. Write events to a log file sequentially; stops when the file reaches its maximum size.
- FileCircular. Write events to a log file. After the file reaches the maximum size, replace the oldest events with incoming events.
- FileAppend. Append events to an existing sequential log file.
- FileNewFile. Automatically switch to a new log file when the file reaches the maximum size.
- FilePreallocate. Reserve the MaximumFileSize of disk space for the log files in advance.
- Secure. Restrict who can log events to the session to those with TRACELOG_LOG_EVENT permission.
- RealTime. Deliver the events to consumers in real-time instead of writing them to a file. This mode is required for sending the events to the event collector.
- KdFilter. Forward the events though the kernel channel to the event collector or to the debugger.
- UsePagedMemory. Use the paged memory for the buffers.
- NoPerProcessorBuffering. Write the events from all processors to the same buffer. This preserves the order of the events, and is recommended for sending the events to the event collector.
The acceptable values for this parameter are:
- None
- FileNone
- FileSequential
- FileCircular
- FileAppend
- FileNewFile
- Reserved0x00000010
- FilePreallocate
- Nonstoppable
- Secure
- RealTime
- DelayOpenFile
- Buffering
- PrivateLogger
- AddHeader
- UseKilobytesForSize
- UseGlobalSequence
- Relog
- PrivateInProc
- BufferInterface
- KdFilter
- RealtimeRelog
- LostEventsDebug
- StopOnHybridShutdown
- PersistOnHybridShutdown
- UsePagedMemory
- SystemLogger
- Compressed
- IndependentSession
- NoPerProcessorBuffering
- Blocking
- Reserved0x40000000
- AddToTriageDump
Type: | LoggingMode |
Accepted values: | None, FileNone, FileSequential, FileCircular, FileAppend, FileNewFile, Reserved0x00000010, FilePreallocate, Nonstoppable, Secure, RealTime, DelayOpenFile, Buffering, PrivateLogger, AddHeader, UseKilobytesForSize, UseGlobalSequence, UseLocalSequence, Relog, PrivateInProc, BufferInterface, KdFilter, RealtimeRelog, LostEventsDebug, StopOnHybridShutdown, PersistOnHybridShutdown, UsePagedMemory, SystemLogger, Compressed, IndependentSession, NoPerProcessorBuffering, Blocking, Reserved0x40000000, AddToTriageDump |
Position: | 12 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-MaximumBufferCount
Specifies the maximum number of buffers to allocate for this session.
Type: | UInt32 |
Aliases: | MaximumBuffers, maxbuf |
Position: | 9 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-MaximumFileSize
Specifies the maximum file size after which the session may switch to the next file, in megabytes. Specify 0 for no limit.
Type: | UInt32 |
Position: | 10 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-MinimumBufferCount
Specifies the minimum number of buffers to allocate for this session.
Type: | UInt32 |
Aliases: | MinimumBuffers, minbuf |
Position: | 8 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-Name
Specifies the name of the session to start.
Type: | String |
Position: | 0 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-PassThru
Returns an object representing the item with which you are working. By default, this cmdlet does not generate any output.
Type: | SwitchParameter |
Position: | Named |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-Path
Specifies the ETL file where the session will write its log. The session must have the file mode enabled to write to a file; a session in real-time mode ignores the file.
Type: | String |
Position: | 1 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-ProviderGuid
Specifies the provider GUIDs to subscribe this session to. The providers are configured to include all events up to the level specified by the Level parameter.
Type: | Guid[] |
Aliases: | pg |
Position: | 4 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-ProviderName
Specifies the provider names to subscribe this session to. The providers are configured to include all events up to the level specified by the Level parameter
Type: | String[] |
Aliases: | pn |
Position: | 3 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-SessionGuid
Specifies the GUID for the session.
Type: | Guid |
Position: | 2 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-SimulateCreationError
Simulates a Windows error in session creation, and causes the function to throw an error. You can specify this parameter to test error handling.
Type: | Int32 |
Position: | 14 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-SimulateSubscriptionError
Simulates a Windows error in session subscription, and causes the function to throw an error. You can specify this parameter to test error handling.
Type: | Int32 |
Position: | 15 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Syntax
Start-SbecLogSession [-Name] <String> [[-Path] <String>] [[-SessionGuid] <Guid>] [[-ProviderName] <String[]>] [[-ProviderGuid] <Guid[]>] [[-Level] <SeverityLevel>] [[-ClockType] <ClientContext>] [[-BufferSize] <UInt32>] [[-MinimumBufferCount] <UInt32>] [[-MaximumBufferCount] <UInt32>] [[-MaximumFileSize] <UInt32>] [[-FlushSeconds] <UInt32>] [[-LogFileMode] <LoggingMode>] [[-KernelEnableFlags] <EventTraceFlag>] [-PassThru] [[-SimulateCreationError] <Int32>] [[-SimulateSubscriptionError] <Int32>] [<CommonParameters>]
You can check the Version, CommandType and Source of this cmdlet by giving below command.
Get-Command Start-SbecLogSession
You can also read about
- Get-SbecLogSession
- Save-SbecLogSession
- Set-SbecLogSession
- Start-SbecNtKernelLogSession
- Start-SbecSimpleLogSession
- Stop-SbecLogSession
To know more PowerShell cmdlets(Commands) on BootEventCollector click here